1. Other height requirements and allowances may be applicable pursuant to chapter
138, article X, division 1, section 138-3501, measurement of height and limitations.
2. Other setback requirements and allowance may be applicable pursuant to chapter
138, article X, division 1, section 138-3505, setback measurements, allowances and
restrictions.
3. These development parameters may be superseded by other requirements as part of
an adopted development master plan and/or conditional overlay.
4. Interior attached units: 0-feet, attached end units: 5-feet. For units not located
in individual platted lots, buildings must provide a 10-foot separation from an adjacent
structure. Zero Lot Line detached units shall provide a 0-foot setback on one side
and a 10-foot side setback on the opposite side property line.
5. An additional foot of building setback shall be required for each additional foot
of building height above 50 feet when located on any parcels that abut another parcel
with an existing detached single-family home. Such required additional building setback
shall be measured from the parcel line adjacent to such existing detached single-family
home.
(Ord. No.
18-36
, § 3(Att. B), 10-23-18)